Sudden unexplained death explained?: Difference between revisions

From SUDEP Wiki
Jump to navigation Jump to search
Ycarmen1 (talk | contribs)
Created page with "''Bird J, Dembny K, Sandeman D, and Butler S(1995) Sudden unexplained death explained? Electroencephalography and Clinical Neurophysiology p. 98.'' '''Article not accessible'..."
 
No edit summary
 
(3 intermediate revisions by 2 users not shown)
Line 1: Line 1:
''Bird J, Dembny K, Sandeman D, and Butler S(1995) Sudden unexplained death explained? Electroencephalography and Clinical Neurophysiology p. 98.''
{{Reference
 
|reference=
 
Bird J, Dembny K, Sandeman D, and Butler S(1995) Sudden unexplained death explained? Electroencephalography and Clinical Neurophysiology p. 98.


'''Article not accessible'''
'''Article not accessible'''


'''Abstract:'''
|url=
 
 
|abstract=
 
 
|keywords=
 
 
|context=
 
Single-case report of patient death following seizure while implanted with cortical surface electrodes for surgical planning. The ictal event is described as follows “After 2.5 min of gentle tonic-clonic activity, the nature of the right sided discharges altered, showed a pattern of brief complete flattening alternating with spindling spike discharges for 16 sec and then ceased all activity; the left hemisphere followed with the same pattern and ceased after 8 sec. Individual random nerve firing occurred for a 275 further 60 sec and regular pulse artifact for a further 120 sec.” Authors link this to thalamocortical sleep spindles. It is unclear what happened during attempts to resuscitate the patient.


'''Keywords:'''
|comments=


=Comments and Context]


*
}}

Latest revision as of 18:05, 17 June 2019


Bird J, Dembny K, Sandeman D, and Butler S(1995) Sudden unexplained death explained? Electroencephalography and Clinical Neurophysiology p. 98.

Article not accessible

[ Link to Article]

Abstract:

Keywords:

Context

Single-case report of patient death following seizure while implanted with cortical surface electrodes for surgical planning. The ictal event is described as follows “After 2.5 min of gentle tonic-clonic activity, the nature of the right sided discharges altered, showed a pattern of brief complete flattening alternating with spindling spike discharges for 16 sec and then ceased all activity; the left hemisphere followed with the same pattern and ceased after 8 sec. Individual random nerve firing occurred for a 275 further 60 sec and regular pulse artifact for a further 120 sec.” Authors link this to thalamocortical sleep spindles. It is unclear what happened during attempts to resuscitate the patient.

Comments

Network Graph

Retrieving data for the network graph...