Difference between revisions of "Wrist sensor reveals sympathetic hyperactivity and hypoventilation before probable SUDEP"

From SUDEP Wiki
Jump to navigation Jump to search
(Created page with "''Picard RW, Migliorini M, Caborni C, et al. (2017) Wrist sensor reveals sympathetic hyperactivity and hypoventilation before probable SUDEP. Neurology. 2017 Aug 8;89(6):633-6...")
 
 
Line 1: Line 1:
''Picard RW, Migliorini M, Caborni C, et al. (2017) Wrist sensor reveals sympathetic hyperactivity and hypoventilation before probable SUDEP. Neurology. 2017 Aug 8;89(6):633-635.''
+
{{Reference
  
'''[http://n.neurology.org/content/neurology/89/6/633.full.pdf Link to Article]'''
+
|reference=
 +
 
 +
Picard RW, Migliorini M, Caborni C, et al. (2017) Wrist sensor reveals sympathetic hyperactivity and hypoventilation before probable SUDEP. Neurology. 2017 Aug 8;89(6):633-635.
 +
 
 +
|url=
 +
 
 +
http://n.neurology.org/content/neurology/89/6/633.full.pdf
 +
 
 +
|abstract=
  
 
'''First Paragraph:''' We report a probable sudden unexpected death in epilepsy (SUDEP) in a 20-year-old man wearing a smartwatch that recorded wrist motion via 3-axis accelerometer (ACC) and electrodermal activity (EDA). EDA reflects sympathetic activity without parasympathetic antagonism. The smartwatch (Empatica [Milan, Italy] Embrace, with CE Medical clearance from the European Union for seizure detection) issued an alert, received by the caregiver at 8:50 AM, indicating a probable convulsive seizure. An adult trained in cardiopulmonary resuscitation (CPR) arrived at 9:05 AM, found the patient pulseless, prone, face in pillow with mucus in his mouth, and commenced CPR for 15 minutes without recovery. The family declined autopsy.
 
'''First Paragraph:''' We report a probable sudden unexpected death in epilepsy (SUDEP) in a 20-year-old man wearing a smartwatch that recorded wrist motion via 3-axis accelerometer (ACC) and electrodermal activity (EDA). EDA reflects sympathetic activity without parasympathetic antagonism. The smartwatch (Empatica [Milan, Italy] Embrace, with CE Medical clearance from the European Union for seizure detection) issued an alert, received by the caregiver at 8:50 AM, indicating a probable convulsive seizure. An adult trained in cardiopulmonary resuscitation (CPR) arrived at 9:05 AM, found the patient pulseless, prone, face in pillow with mucus in his mouth, and commenced CPR for 15 minutes without recovery. The family declined autopsy.
  
==Context==
+
|keywords=
 +
 
 +
 
 +
|context=
 +
 
 +
 
 +
|comments=
 +
 
  
==Comments==
+
}}

Latest revision as of 14:13, 17 June 2019


Picard RW, Migliorini M, Caborni C, et al. (2017) Wrist sensor reveals sympathetic hyperactivity and hypoventilation before probable SUDEP. Neurology. 2017 Aug 8;89(6):633-635.

Link to Article

Abstract: First Paragraph: We report a probable sudden unexpected death in epilepsy (SUDEP) in a 20-year-old man wearing a smartwatch that recorded wrist motion via 3-axis accelerometer (ACC) and electrodermal activity (EDA). EDA reflects sympathetic activity without parasympathetic antagonism. The smartwatch (Empatica [Milan, Italy] Embrace, with CE Medical clearance from the European Union for seizure detection) issued an alert, received by the caregiver at 8:50 AM, indicating a probable convulsive seizure. An adult trained in cardiopulmonary resuscitation (CPR) arrived at 9:05 AM, found the patient pulseless, prone, face in pillow with mucus in his mouth, and commenced CPR for 15 minutes without recovery. The family declined autopsy.

Keywords:

Context

Comments

Network Graph

Retrieving data for the network graph...